A clock is the
basis for the normal running of NEs. You must configure clocks for all NEs
prior to configuring services. In addition, you need to configure clock
protection for complex networks.
Configuring clocks on OSN 3500, OSN 7500,
OSN 1500, you should need to do the following steps, we
will show you how to configure the NE clock source this article.
1 Configuring the NE Clock Source
2 Configuring the Clock Source Protection
How to configure the NE clock source
Before
configuring services, you must configure the NE clock source and specify the
priority level to ensure that correct clock tracing relationships are created
for all the NEs in the network.
Prerequisites
You must be an NM
user with NE operator authority or higher.
Background Information
To implement
clock protection, you must configure at least two traceable clock sources for
the equipment. Usually, the tributary clock is not used as the clock source for
the equipment. After you set the clock sources for all the NEs, query the
networkwide clock tracing status again.
Procedure
Step 1 In the NE Explorer, select an NE and choose Configuration > Clock > Physical Layer Clock > Clock Source
Priority from the Function Tree.
Step 2 Click Query to query the
existing clock source.
Step 3 Click Create. In the Add
Clock Source dialog box, select a new clock source and click OK.
Step 4 Optional: If an external clock source is selected, select External
Clock Source Mode based on the type of external clock signals. In the case 2
Mbit/s clocks, specify Synchronous Status Byte to deliver SSM messages.
Step 5 Select a clock source, and click
to
adjust its priority level. The clock sources are arranged in descending order.
The clock source on top is preferred for the NE.
NOTE
Internal clock
sources have the lowest priority because of their low precision.
Step 6 Click Apply. In the Operation
Result dialog box, click Close.
NOTE
If the
clock tracing relationship changes because of change in the clock source, the
Prompt dialog box is displayed, asking you whether to refresh the clock tracing
relationship. Click OK. If you select Disable Prompting Next Time, no prompt is
displayed even when the clock tracing relationship changes.
Step 7 Optional: If you select the line clock as the phase-locked
source, you need to specify the priority table for the phase-locked sources. Click
the Priority Table for Phase-Locked Sources of 1st External Clock
Output tab, and then click Create. In the dialog box that is displayed, select the
phase-locked source, and click OK.
Step 8 Click Apply. In the dialog
box that is displayed, click Close.
----End
没有评论:
发表评论