Creating Inter-Board Port Protection Groups

TPS, 1+1 board protection, board level protection, and port protection. Addition: OSN 8800 the different version the configuration would be different.

Creating Inter-Board Port Protection Groups

The inter-board port protection switching (PPS) is a protection scheme based on ports between boards. This protection scheme requires an active board and a standby board. When the active board detects a link down failure of any port, or detects a board hardware failure, the crossconnect board on the equipment switches the services of one or more affected ports to the standby board. In this case, a protection switching of the entire board is not required. Compared with the board protection switching (BPS), the PPS has less impact on external systems and the network.

Prerequisites
1 You must be an NM user with NE operator authority or higher.
2 The Ethernet boards must be installed in pairs. There must be no services on the protection board.
3 The available bandwidth of the protection board is higher than or equal to the available
bandwidth of the working board. In addition, the interface boards must be of the same type
and quantity.
4 The same EMS4/EGS4 board cannot be configured with BPS and PPS simultaneously.
5 Before configuring the PPS for the Huawei SDH EMS4 board, you must set the working mode of the
corresponding interface board such as N1ETF8/N1EFF8 to 100M full-duplex.

Context
When the following prerequisites are met, the protection group can be switched automatically.
1 The equipment that is interconnected with the protection group has the same working mode as that of the protection group.
2 The transmit end and the receive end should be connected directly through optical fibers
or network cables. There should be no equipment between the two ends.
3 The working mode at the receive end should not be modified before the protection group
is deleted. Otherwise, the protection group works abnormally.

NOTE
1 After the inter-board port protection group is created, the protection port cannot be used to transmit other services.
2 Add all the ports to the port protection group when you configure an inter-board port protection group.
3 The N1EMS4, N1EGS4, and N3EGS4 boards support the inter-board port protection.
4 Configuration of the intra-board port protection is similar to the configuration of the inter-board port protection. The difference is that the configuration of the intra-board port protection is based on different ports on the same board.

Procedure
Step 1 In the NE Explorer, select an NE and choose Configuration > Port Protection from the Function Tree.
Step 2 Click New and the Create Port Protection Group dialog box is displayed.

Step 3 Enter Protection Group ID, select Working Port and Protection Port.
NOTE
If you directly click OK without specifying the Protection Group ID, the system automatically allocates the protection group ID. Click OK in the Warning dialog box.

Step 4 Click OK. A prompt dialog box is displayed, indicating that the operation is successful.

Step 5 Click Close.
----End